Name | Data Type | Default Value | Qualifiers |
Name | Data Type | Value |
EthernetNICTestType | uint16 | |
Description | string | The descriptions for each Ethernet NIC test type are below: * "MAC Register" (value=2) is specified for the tests that verify the functionality of the general CPU instruction. CIM_DiagnosticTest.TestTypes shall be set to "Functional" (value=2). * "Physical Register" (value=3) is specified for the tests that verify the functionality of the FPU instructions. CIM_DiagnosticTest.TestTypes shall be set to "Functional" (value=2). * "Internal Loopback" (value=4) is specified for the tests that verify that all internal data paths of an Ethernet NIC is working properly. CIM_DiagnosticTest.TestTypes shall be set to "Functional" (value=2). * "External Loopback" (value=5) is specified for the tests that verify that all external data paths of an Ethernet NIC is working properly. CIM_DiagnosticTest.TestTypes shall be set to "Access Test" (value=5). * "Beacon" (value=6) is specified for the tests that cause at least one of the LEDs of a Ethernet NIC to flash on and off. CIM_DiagnosticTest.TestTypes shall be set to "Functional" (value=2). * "Self" (value=7) is specified for the tests that verify the functionality of all possible components of the Ethernet NIC CIM_DiagnosticTest.TestTypes shall be set to "Functional" (value=2). * "Status" (value=8) is specified for the tests that verify the healthof the Ethernet NIC. CIM_DiagnosticTest.TestTypes shall be set to "Health Check" (value=4). * "Ping" (value=9) is specified for the tests that verify access to the network. CIM_DiagnosticTest.TestTypes shall be set to "Stress" (value=3). * "Embedded Processor" (value=10) is specified for the tests that verify functionality of the embedded processor. CIM_DiagnosticTest.TestTypes shall be set to "Functional" (value=2). * "IRQ" (value=11) is specified for the tests that verify functionality of raising interrupts. CIM_DiagnosticTest.TestTypes shall be set to "Functional" (value=2)." |
ModelCorrespondence | string | CIM_EthernetNICDiagnosticTest.OtherEthernetNICTestTypeDescription |
ValueMap | string | 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, .., 0x8000.. |
Values | string | Unknown, Other, MAC Register, Physical Register, Internal Loopback, External Loopback, Beacon, Self, Status, Ping, Embedded Processor, IRQ, DMTF Reserved, Vendor Reserved |
OtherEthernetNICTestTypeDescription | string | |
Description | string | A string that describes the test when the EthernetNICTestType property is set to 1 ("Other"). This property must be set to null when EthernetNICTestType is any value other than 1. |
ModelCorrespondence | string | CIM_EthernetNICDiagnosticTest.EthernetNICTestType |