Name | Data Type | Default Value | Qualifiers |
Name | Data Type | Value |
DomainIDLocked | boolean | |
Description | string | Boolean that indicates if the switch can negotiate a new domainID when the configured domainID is unavailable. If this value is true, a domainID conflict will cause the fabric merge process to fail. |
MappingStrings | string | FC-SWAPI.INCITS-T11|UcUnitConfigGetDomainIDLocked |
ModelCorrespondence | string | CIM_FCSwitchSettings.PreferredDomainID |
Write | boolean | true |
PreferredDomainID | uint8 | |
Description | string | The preferred domainID for the switch. If DomainIDLocked is true, then this property will be the required DomainID for the switch. |
MappingStrings | string | FC-SWAPI.INCITS-T11|UcUnitConfigGetDomainID, GC-GS.INCITS-T11|InterconnectElement|DomainIdentifier |
MaxValue | sint64 | 239 |
MinValue | sint64 | 1 |
ModelCorrespondence | string | CIM_FCSwitchSettings.DomainIDLocked |
Write | boolean | true |
PrincipalPriority | uint16 | 3 |
Description | string | This value affects the selection of a principal switch within the fabric. The value indirectly corresponds to the FC-FS switch_priority value used during principal switch selection.
- Principal: Attempt to become the principal switch in the fabric.
- Subordinate: Attempt not to become the principal switch in the fabric.
- Any: No preference. |
MappingStrings | string | FC-SWAPI.INCITS-T11|SWAPI_PRINCIPAL_PRIORITY_T |
ValueMap | string | 2, 3, 4 |
Values | string | Principal, Subordinate, Any |
Write | boolean | true |