Name | Data Type | Default Value | Qualifiers |
Name | Data Type | Value |
Classification | uint32 | |
Description | string | Indicates whether this PrintSupply instance represents a PrintSupply that is consumed or a receptacle that is filled. |
MappingStrings | string | MIB.IETF|Printer-MIB.prtMarkerSuppliesClass, MIB.IETF|Finisher-MIB.finSupplyClass, MIB.IETF|Printer-MIB.PrtMarkerSuppliesClassTC |
ModelCorrespondence | string | CIM_PrintSupply.OtherClassification |
ValueMap | string | 1, 3, 4, .. |
Values | string | Other, SupplyThatIsConsumed, ReceptacleThatIsFilled, DMTF Reserved |
ColorantName | uint16 | |
Description | string | If this PrintSupply does not represent a PrintMarker colorant, then this property shall be null. If this PrintSupply does represent a PrintMarker colorant, then this property shall be present and shall denote the colorant name using the standardized names from ISO 10175 (DPA) and ISO 10180 (SPDL). Vendors and administrators may specify other colorant names in the OtherColorantName property. |
MappingStrings | string | MIB.IETF|Printer-MIB.prtMarkerColorantValue |
ModelCorrespondence | string | CIM_PrintSupply.OtherColorantName |
ValueMap | string | 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, .. |
Values | string | Other, Unknown, White, Red, Green, Blue, Cyan, Magenta, Yellow, Black, DMTF Reserved |
ColorantRole | uint32 | |
Description | string | If this PrintSupply does not represent a PrintMarker colorant, then this property shall be null. If this PrintSupply does represent a PrintMarker colorant, then this property shall be present and shall denote the role played by this PrintMarker colorant. |
MappingStrings | string | MIB.IETF|Printer-MIB.prtMarkerColorantRole, MIB.IETF|Printer-MIB.PrtMarkerColorantRoleTC |
ModelCorrespondence | string | CIM_PrintSupply.OtherColorantRole, CIM_PrintMarker.ProcessColorants, CIM_PrintMarker.SpotColorants |
ValueMap | string | 1, 3, 4, .. |
Values | string | Other, Process, Spot, DMTF Reserved |
ColorantTonality | uint32 | |
Description | string | If this PrintSupply does not represent a PrintMarker colorant, then this property shall be null. If this PrintSupply does represent a PrintMarker colorant, then this property shall be present and shall denote the distinct levels of tonality realizable by a PrintMarker when using this colorant. This value does not include the number of levels of tonal difference that an interpreter can obtain by techniques such as half toning. This value must be at least 2. |
MappingStrings | string | MIB.IETF|Printer-MIB.prtMarkerColorantTonality |
MaxValue | sint64 | 2147483647 |
MinValue | sint64 | 2 |
LocalizedDescription | string | |
Description | string | A free-form text description of this PrintSupply in the localization specified by CIM_Printer.CurrentNaturalLanguage. |
MappingStrings | string | MIB.IETF|Printer-MIB.prtMarkerSuppliesDescription, MIB.IETF|Finisher-MIB.finSupplyDescription, MIB.IETF|Printer-MIB.PrtLocalizedDescriptionStringTC |
MaxLen | uint32 | 255 |
ModelCorrespondence | string | CIM_Printer.CurrentNaturalLanguage |
MaxCapacity | uint32 | |
Description | string | The maximum capacity of this PrintSupply container (for a supply that is consumed) or receptacle (for waste that is produced) in units specified by CIM_PrintSupply.SupplyUnit. If this Printer can reliably sense this value, the value is sensed by the Printer and cannot be changed by the system administrator; otherwise, the value may be changed out-of-band by the system administrator. |
MappingStrings | string | MIB.IETF|Printer-MIB.prtMarkerSuppliesMaxCapacity, MIB.IETF|Finisher-MIB.finSuppyMaxCapacity, MIB.IETF|Printer-MIB.prtMarkerSuppliesSupplyUnit, MIB.IETF|Finisher-MIB.finSupplyUnit, MIB.IETF|Printer-MIB.PrtMarkerSuppliesSupplyUnitTC |
MaxValue | sint64 | 2147483647 |
MinValue | sint64 | 0 |
ModelCorrespondence | string | CIM_PrintSupply.MaxCapacityBasis |
MaxCapacityBasis | uint16 | |
Description | string | The basis for the limit property MaxCapacity, that specifies whether a meaningful value is available. 1 (Other) means the Printer places no restrictions on capacity and MaxCapacity shall be null. 2 (Unknown) means the Printer cannot sense a meaningful value and MaxCapacity shall be null. 3 (Actual) means the Printer can sense a meaningful value and MaxCapacity shall be present. |
MappingStrings | string | MIB.IETF|Printer-MIB.prtMarkerSuppliesMaxCapacity, MIB.IETF|Finisher-MIB.finSuppyMaxCapacity |
ModelCorrespondence | string | CIM_PrintSupply.MaxCapacity |
ValueMap | string | 1, 2, 3, .. |
Values | string | Other, Unknown, Actual, DMTF Reserved |
OtherClassification | string | |
Description | string | A free-form string that describes the PrintSupply classification when the value of the Classification property is equal to 1 (Other). |
MaxLen | uint32 | 255 |
ModelCorrespondence | string | CIM_PrintSupply.Classification |
OtherColorantName | string | |
Description | string | If this PrintSupply does not represent a PrintMarker colorant, then this property shall be null. If this PrintSupply does represent a PrintMarker colorant and the value of the ColorantName property is equal to 1 (Other), then this property shall be present and shall contain a vendor or administrator defined value. The naming conventions in ISO 9070 are recommended in order to avoid potential name clashes. |
MaxLen | uint32 | 255 |
ModelCorrespondence | string | CIM_PrintSupply.ColorantName |
OtherColorantRole | string | |
Description | string | If this PrintSupply does not represent a PrintMarker colorant, then this property shall be null. If this PrintSupply does represent a PrintMarker colorant and the value of the ColorantRole property is equal to 1 (Other), then this property shall be present and shall contain a free-form string that describes the role of the colorant. |
MaxLen | uint32 | 255 |
ModelCorrespondence | string | CIM_PrintSupply.ColorantRole |
OtherSupplyUnit | string | |
Description | string | A free-form string that describes the PrintSupply unit when the value of the SupplyUnit property is equal to 1 (Other). |
MaxLen | uint32 | 255 |
ModelCorrespondence | string | CIM_PrintSupply.SupplyUnit |
OtherTypeDescription | string | |
Description | string | A free-form string that describes the PrintSupply type when the value of the Type property is equal to 1 (Other). |
MaxLen | uint32 | 255 |
ModelCorrespondence | string | CIM_PrintSupply.Type |
RemainingCapacity | uint32 | |
Description | string | The current remaining level of the supply if this PrintSupply is a container (for a supply that is consumed) or the remaining capacity if this PrintSupply is a receptacle (for waste that is produced), in units specified by CIM_PrintSupply.SupplyUnit. If this Printer can reliably sense this value, the value is sensed by the Printer and cannot be changed by the system administrator; otherwise, the value may be changed out-of-band by the system administrator. |
MappingStrings | string | MIB.IETF|Printer-MIB.prtMarkerSuppliesLevel, MIB.IETF|Finisher-MIB.finSuppyCurrentLevel, MIB.IETF|Printer-MIB.prtMarkerSuppliesSupplyUnit, MIB.IETF|Finisher-MIB.finSupplyUnit, MIB.IETF|Printer-MIB.PrtMarkerSuppliesSupplyUnitTC |
MaxValue | sint64 | 2147483647 |
MinValue | sint64 | 0 |
ModelCorrespondence | string | CIM_PrintSupply.RemainingCapacityBasis |
RemainingCapacityBasis | uint16 | |
Description | string | The basis for the gauge property RemainingCapacity, that specifies whether a meaningful value is available. 1 (Other) means the Printer places no restrictions on capacity and RemainingCapacity shall be null. 2 (Unknown) means the Printer cannot sense a meaningful value and RemainingCapacity shall be null. 3 (Actual) means the Printer can sense a meaningful value and RemainingCapacity shall be present. 4 (AtLeastOne) means that the Printer can only sense that at least one capacity unit remains and RemainingCapacity shall be present and shall contain the value zero or one. |
MappingStrings | string | MIB.IETF|Printer-MIB.prtMarkerSuppliesLevel, MIB.IETF|Finisher-MIB.finSuppyCurrentLevel |
ModelCorrespondence | string | CIM_PrintSupply.RemainingCapacity |
ValueMap | string | 1, 2, 3, 4, .. |
Values | string | Other, Unknown, Actual, AtLeastOne, DMTF Reserved |
SupplyUnit | uint32 | |
Description | string | Unit of measure for this PrintSupply container (for a supply that is consumed) or receptacle (for waste that is produced). |
MappingStrings | string | MIB.IETF|Printer-MIB.prtMarkerSuppliesSupplyUnit, MIB.IETF|Finisher-MIB.finSupplyUnit, MIB.IETF|Printer-MIB.PrtMarkerSuppliesSupplyUnitTC |
ModelCorrespondence | string | CIM_PrintSupply.OtherSupplyUnit |
ValueMap | string | 1, 2, 3, 4, 7, 8, 11, 12, 13, 14, 15, 16, 17, 18, 19, .. |
Values | string | Other, Unknown, TenThousandthsOfInches, Micrometers, Impressions, Sheets, Hours, ThousandthsOfOunces, TenthsOfGrams, HundrethsOfFluidOunces, TenthsOfMilliliters, Feet, Meters, Items, Percent, DMTF Reserved |
Type | uint32 | |
Description | string | The type of this PrintSupply. |
MappingStrings | string | MIB.IETF|Printer-MIB.prtMarkerSuppliesType, MIB.IETF|Finisher-MIB.finSupplyType, MIB.IETF|IANA-PRINTER-MIB.PrtMarkerSuppliesTypeTC |
ModelCorrespondence | string | CIM_PrintSupply.OtherTypeDescription |
ValueMap | string | 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, .. |
Values | string | Other, Unknown, Toner, WasteToner, Ink, InkCartridge, InkRibbon, WasteInk, Opc, Developer, FuserOil, SolidWax, RibbonWax, WasteWax, Fuser, CoronaWire, FuserOilWick, CleanerUnit, FuserCleaningPad, TransferUnit, TonerCartridge, FuserOiler, Water, WasteWater, GlueWaterAdditive, WastePaper, BindingSupply, BandingSupply, StitchingWire, ShrinkWrap, PaperWrap, Staples, Inserts, Covers, DMTF Reserved |