Name | Data Type | Value |
---|---|---|
Description | string | Capabilities and management of an UninterruptiblePowerSupply. The properties of the UPS Device indicate when incoming power is trimmed or boosted, and the aggregated information of the batteries, generators, and so on that comprise the Device. These individual components (for example, multiple batteries) can also be independently modeled and associated with the UPS. |
UMLPackagePath | string | CIM::Device::CoolingAndPower |
Version | string | 2.10.0 |
Name | Data Type | Default Value | Qualifiers | ||||
---|---|---|---|---|---|---|---|
Name | Data Type | Value | |||||
EstimatedChargeRemaining | uint16 | ||||||
Description | string | An estimate of the percentage of full charge remaining for a UPS (that uses battery technology). | |||||
Gauge | boolean | true | |||||
MappingStrings | string | MIF.DMTF|UPS Battery|001.4 | |||||
PUnit | string | percent | |||||
Units | string | Percent | |||||
EstimatedRunTime | uint32 | ||||||
Description | string | EstimatedRunTime is an estimate in minutes of the time that depletion of the battery, generator, or other device, will occur under the present load conditions if the utility power is off or is lost and remains off. | |||||
MappingStrings | string | MIF.DMTF|UPS Battery|001.3 | |||||
PUnit | string | minute | |||||
Units | string | Minutes | |||||
Range1InputVoltageHigh | uint32 | ||||||
Description | string | If the voltage (in millivolts) rises above the value specified by Range1InputVoltageHigh, the UPS will compensate by trimming the voltage. A value of 0 indicates that the voltage at which trimming occurs is 'unknown'. | |||||
MappingStrings | string | MIF.DMTF|Power Supply|004.8 | |||||
Override | string | Range1InputVoltageHigh | |||||
PUnit | string | volt * 10^-3 | |||||
Units | string | MilliVolts | |||||
Range1InputVoltageLow | uint32 | ||||||
Description | string | If the voltage (in millivolts) drops below the value specified by Range1InputVoltageLow, the UPS will compensate by boosting the voltage using its power sources. A value of 0 indicates that the voltage at which boosting occurs is 'unknown'. | |||||
MappingStrings | string | MIF.DMTF|Power Supply|004.7 | |||||
Override | string | Range1InputVoltageLow | |||||
PUnit | string | volt * 10^-3 | |||||
Units | string | MilliVolts | |||||
Range2InputVoltageHigh | uint32 | ||||||
Description | string | If the voltage (in millivolts) rises above the value specified by Range2InputVoltageHigh, the UPS will compensate by trimming the voltage. A value of 0 indicates that the voltage at which trimming occurs is 'unknown'. | |||||
MappingStrings | string | MIF.DMTF|Power Supply|004.12 | |||||
Override | string | Range2InputVoltageHigh | |||||
PUnit | string | volt * 10^-3 | |||||
Units | string | MilliVolts | |||||
Range2InputVoltageLow | uint32 | ||||||
Description | string | If the voltage (in millivolts) drops below the value specified by Range2InputVoltageLow, the UPS will compensate by boosting the voltage using its power sources. A value of 0 indicates that the voltage at which boosting occurs is 'unknown'. | |||||
MappingStrings | string | MIF.DMTF|Power Supply|004.11 | |||||
Override | string | Range2InputVoltageLow | |||||
PUnit | string | volt * 10^-3 | |||||
Units | string | MilliVolts | |||||
RemainingCapacityStatus | uint16 | ||||||
Description | string | The indication of the capacity that remains in the UPS batteries, generator, and so on. A value of "Normal" (2) indicates that the remaining estimated minutes of run-time are greater than the 'low power' state defined for the UPS (typically two minutes). A value of "Low" (3) indicates that the remaining estimated minutes of run-time are less than or equal to the defined 'low power' state of the device. A value of "Depleted" (4) indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is currently absent). | |||||
MappingStrings | string | MIF.DMTF|UPS Battery|001.1 | |||||
ValueMap | string | 1, 2, 3, 4 | |||||
Values | string | Unknown, Normal, Low, Depleted | |||||
TimeOnBackup | uint32 | ||||||
Description | string | TimeOnBackup indicates the elapsed time in seconds since the UPS last switched to battery power, generator, or so on or the time since the UPS was last restarted, whichever is less. 0 is returned if the UPS is 'on line'. | |||||
MappingStrings | string | MIF.DMTF|UPS Battery|001.2 | |||||
PUnit | string | second | |||||
Units | string | Seconds |
Name | Data Type | Class Origin |
---|---|---|
ActiveInputVoltage | uint16 | CIM_PowerSupply |
Availability | uint16 | CIM_LogicalDevice |
Caption | string | CIM_ManagedElement |
CommunicationStatus | uint16 | CIM_ManagedSystemElement |
CreationClassName | string | CIM_LogicalDevice |
Description | string | CIM_ManagedElement |
DetailedStatus | uint16 | CIM_ManagedSystemElement |
DeviceID | string | CIM_LogicalDevice |
ElementName | string | CIM_ManagedElement |
EnabledDefault | uint16 | CIM_EnabledLogicalElement |
EnabledState | uint16 | CIM_EnabledLogicalElement |
ErrorCleared | boolean | CIM_LogicalDevice |
ErrorDescription | string | CIM_LogicalDevice |
Generation | uint64 | CIM_ManagedElement |
HealthState | uint16 | CIM_ManagedSystemElement |
InputPowerUnits | string | CIM_PowerSupply |
InstallDate | datetime | CIM_ManagedSystemElement |
InstanceID | string | CIM_ManagedElement |
IsACInput | boolean | CIM_PowerSupply |
IsACOutput | boolean | CIM_PowerSource |
IsSwitchingSupply | boolean | CIM_PowerSupply |
LastErrorCode | uint32 | CIM_LogicalDevice |
LocationIndicator | uint16 | CIM_LogicalDevice |
MaxQuiesceTime | uint64 | CIM_LogicalDevice |
Name | string | CIM_ManagedSystemElement |
NumberOfPhasesUtilized | uint32 | CIM_PowerSupply |
OperatingStatus | uint16 | CIM_ManagedSystemElement |
OtherEnabledState | string | CIM_EnabledLogicalElement |
OutputPowerUnits | string | CIM_PowerSupply |
PowerManagementSupported | boolean | CIM_LogicalDevice |
PowerOnHours | uint64 | CIM_LogicalDevice |
PrimaryStatus | uint16 | CIM_ManagedSystemElement |
Range1InputFrequencyHigh | uint32 | CIM_PowerSupply |
Range1InputFrequencyLow | uint32 | CIM_PowerSupply |
Range1MaxInputPower | uint32 | CIM_PowerSupply |
Range1MaxOutputPower | uint32 | CIM_PowerSupply |
Range2InputFrequencyHigh | uint32 | CIM_PowerSupply |
Range2InputFrequencyLow | uint32 | CIM_PowerSupply |
Range2MaxInputPower | uint32 | CIM_PowerSupply |
Range2MaxOutputPower | uint32 | CIM_PowerSupply |
RatedMaxOutputPower | uint32 | CIM_PowerSource |
RequestedState | uint16 | CIM_EnabledLogicalElement |
Status | string | CIM_ManagedSystemElement |
StatusInfo | uint16 | CIM_LogicalDevice |
SystemCreationClassName | string | CIM_LogicalDevice |
SystemName | string | CIM_LogicalDevice |
TimeOfLastStateChange | datetime | CIM_EnabledLogicalElement |
TotalOutputPower | uint32 | CIM_PowerSupply |
TotalPowerOnHours | uint64 | CIM_LogicalDevice |
TransitioningToState | uint16 | CIM_EnabledLogicalElement |
TypeOfRangeSwitching | uint16 | CIM_PowerSupply |
AdditionalAvailability | uint16[] | CIM_LogicalDevice |
AvailableRequestedStates | uint16[] | CIM_EnabledLogicalElement |
IdentifyingDescriptions | string[] | CIM_LogicalDevice |
NominalPhaseWiring | uint32[] | CIM_PowerSupply |
OperationalStatus | uint16[] | CIM_ManagedSystemElement |
OtherIdentifyingInfo | string[] | CIM_LogicalDevice |
PowerManagementCapabilities | uint16[] | CIM_LogicalDevice |
StatusDescriptions | string[] | CIM_ManagedSystemElement |
Name | Return Type | Class Origin |
---|---|---|
EnableDevice | uint32 | CIM_LogicalDevice |
OnlineDevice | uint32 | CIM_LogicalDevice |
QuiesceDevice | uint32 | CIM_LogicalDevice |
RequestStateChange | uint32 | CIM_EnabledLogicalElement |
Reset | uint32 | CIM_LogicalDevice |
RestoreProperties | uint32 | CIM_LogicalDevice |
SaveProperties | uint32 | CIM_LogicalDevice |
SetPowerState | uint32 | CIM_LogicalDevice |