Name | Data Type | Value |
---|---|---|
Deprecated | string | CIM_RedundancySet |
Description | string | A class derived from RedundancyGroup indicating that the aggregated elements have more capacity or capability than is needed. An example of this type of redundancy is the installation of N+1 power supplies or fans in a system. The use of this class is being deprecated in lieu of using RedundancySet. |
UMLPackagePath | string | CIM::Core::Redundancy |
Version | string | 2.21.0 |
Name | Data Type | Default Value | Qualifiers | ||||
---|---|---|---|---|---|---|---|
Name | Data Type | Value | |||||
LoadBalancedGroup | boolean | ||||||
Deprecated | string | CIM_RedundancySet.TypeOfSet | |||||
Description | string | Boolean indicating whether load balancing is supported by the ExtraCapacityGroup. | |||||
MinNumberNeeded | uint32 | ||||||
Deprecated | string | CIM_RedundancySet.MinNumberNeeded | |||||
Description | string | MinNumberNeeded indicates the smallest number of elements that must be operational in order to have redundancy. For example, in an N+1 redundancy relationship, the MinNumberNeeded property should be set equal to N. |
Name | Data Type | Class Origin |
---|---|---|
Caption | string | CIM_ManagedElement |
CommunicationStatus | uint16 | CIM_ManagedSystemElement |
CreationClassName | string | CIM_RedundancyGroup |
Description | string | CIM_ManagedElement |
DetailedStatus | uint16 | CIM_ManagedSystemElement |
ElementName | string | CIM_ManagedElement |
HealthState | uint16 | CIM_ManagedSystemElement |
InstallDate | datetime | CIM_ManagedSystemElement |
InstanceID | string | CIM_ManagedElement |
Name | string | CIM_RedundancyGroup |
OperatingStatus | uint16 | CIM_ManagedSystemElement |
PrimaryStatus | uint16 | CIM_ManagedSystemElement |
RedundancyStatus | uint16 | CIM_RedundancyGroup |
Status | string | CIM_ManagedSystemElement |
OperationalStatus | uint16[] | CIM_ManagedSystemElement |
StatusDescriptions | string[] | CIM_ManagedSystemElement |