Name | Data Type | Value |
---|---|---|
Description | string | The CIM_HardwareThread class inherits from CIM_EnabledLogicalElement and represents a specific processor hardware thread. CIM_HardwareThread instances are related to the CIM_ProcessorCore instance they are based on. |
UMLPackagePath | string | CIM::Device::Processor |
Version | string | 2.22.0 |
Name | Data Type | Default Value | Qualifiers | ||||
---|---|---|---|---|---|---|---|
Name | Data Type | Value | |||||
InstanceID | string | ||||||
Description | string | Within the scope of the instantiating Namespace, InstanceID opaquely and uniquely identifies an instance of this class. In order to ensure uniqueness within the NameSpace, the value of InstanceID SHOULD be constructed using the following 'preferred' algorithm: <OrgID>:<LocalID> Where <OrgID> and <LocalID> are separated by a colon ':', and where <OrgID> MUST include a copyrighted, trademarked or otherwise unique name that is owned by the business entity creating/defining the InstanceID, or is a registered ID that is assigned to the business entity by a recognized global authority (This is similar to the <Schema Name>_<Class Name> structure of Schema class names.) In addition, to ensure uniqueness <OrgID> MUST NOT contain a colon (':'). When using this algorithm, the first colon to appear in InstanceID MUST appear between <OrgID> and <LocalID>. <LocalID> is chosen by the business entity and SHOULD not be re-used to identify different underlying (real-world) elements. If the above 'preferred' algorithm is not used, the defining entity MUST assure that the resultant InstanceID is not re-used across any InstanceIDs produced by this or other providers for this instance's NameSpace. For DMTF defined instances, the 'preferred' algorithm MUST be used with the <OrgID> set to 'CIM'. | |||||
Key | boolean | true | |||||
Override | string | InstanceID | |||||
LoadPercentage | uint16 | ||||||
Description | string | Loading of this processor hardware thread, averaged over the last minute, in Percent. | |||||
Gauge | boolean | true | |||||
PUnit | string | percent | |||||
Units | string | Percent |
Name | Data Type | Class Origin |
---|---|---|
Caption | string | CIM_ManagedElement |
CommunicationStatus | uint16 | CIM_ManagedSystemElement |
Description | string | CIM_ManagedElement |
DetailedStatus | uint16 | CIM_ManagedSystemElement |
ElementName | string | CIM_ManagedElement |
EnabledDefault | uint16 | CIM_EnabledLogicalElement |
EnabledState | uint16 | CIM_EnabledLogicalElement |
HealthState | uint16 | CIM_ManagedSystemElement |
InstallDate | datetime | CIM_ManagedSystemElement |
Name | string | CIM_ManagedSystemElement |
OperatingStatus | uint16 | CIM_ManagedSystemElement |
OtherEnabledState | string | CIM_EnabledLogicalElement |
PrimaryStatus | uint16 | CIM_ManagedSystemElement |
RequestedState | uint16 | CIM_EnabledLogicalElement |
Status | string | CIM_ManagedSystemElement |
TimeOfLastStateChange | datetime | CIM_EnabledLogicalElement |
TransitioningToState | uint16 | CIM_EnabledLogicalElement |
AvailableRequestedStates | uint16[] | CIM_EnabledLogicalElement |
OperationalStatus | uint16[] | CIM_ManagedSystemElement |
StatusDescriptions | string[] | CIM_ManagedSystemElement |
Name | Return Type | Class Origin |
---|---|---|
RequestStateChange | uint32 | CIM_EnabledLogicalElement |