Name | Data Type | Default Value | Qualifiers |
Name | Data Type | Value |
ActiveInputVoltage | uint16 | |
Description | string | ActiveInputVoltage indicates which input voltage range is currently in use. Range 1, 2, or both can be specified using the values 3, 4, or 5, respectively. If the Supply is not currently drawing power, the value 6 ("Neither") can be specified. This information is necessary in the case of a UPS, a subclass of PowerSupply. |
MappingStrings | string | MIF.DMTF|Power Supply|004.15 |
ValueMap | string | 1, 2, 3, 4, 5, 6 |
Values | string | Other, Unknown, Range 1, Range 2, Both, Neither |
IsSwitchingSupply | boolean | |
Description | string | Boolean indicating that the PowerSupply is a switching (instead of linear) supply. |
Range1InputFrequencyHigh | uint32 | |
Description | string | The frequency (in hertz) at the high end of the Input Frequency Range 1 of this Power Supply. A value of 0 implies DC. |
MappingStrings | string | MIF.DMTF|Power Supply|004.18 |
PUnit | string | hertz |
Units | string | Hertz |
Range1InputFrequencyLow | uint32 | |
Description | string | The frequency (in hertz) at the low end of the Input Frequency Range 1 of this Power Supply. A value of 0 implies DC. |
MappingStrings | string | MIF.DMTF|Power Supply|004.17 |
PUnit | string | hertz |
Units | string | Hertz |
Range1InputVoltageHigh | uint32 | |
Description | string | The high voltage of Input Voltage Range 1 for this Power Supply, in millivolts. A value of 0 denotes 'unknown'. |
MappingStrings | string | MIF.DMTF|Power Supply|004.8 |
PUnit | string | volt * 10^-3 |
Units | string | MilliVolts |
Range1InputVoltageLow | uint32 | |
Description | string | The low voltage of Input Voltage Range 1 for this Power Supply, in millivolts. A value of 0 denotes 'unknown'. |
MappingStrings | string | MIF.DMTF|Power Supply|004.7 |
PUnit | string | volt * 10^-3 |
Units | string | MilliVolts |
Range2InputFrequencyHigh | uint32 | |
Description | string | The frequency (in hertz) at the high end of the Input Frequency Range 2 of this Power Supply. A value of 0 implies DC. |
MappingStrings | string | MIF.DMTF|Power Supply|004.20 |
PUnit | string | hertz |
Units | string | Hertz |
Range2InputFrequencyLow | uint32 | |
Description | string | The frequency (in hertz) at the low end of the Input Frequency Range 2 of this Power Supply. A value of 0 implies DC. |
MappingStrings | string | MIF.DMTF|Power Supply|004.19 |
PUnit | string | hertz |
Units | string | Hertz |
Range2InputVoltageHigh | uint32 | |
Description | string | The high voltage of Input Voltage Range 2 for this Power Supply, in millivolts. A value of 0 denotes 'unknown'. |
MappingStrings | string | MIF.DMTF|Power Supply|004.12 |
PUnit | string | volt * 10^-3 |
Units | string | MilliVolts |
Range2InputVoltageLow | uint32 | |
Description | string | The low voltage of Input Voltage Range 2 for this Power Supply, in millivolts. A value of 0 denotes 'unknown'. |
MappingStrings | string | MIF.DMTF|Power Supply|004.11 |
PUnit | string | volt * 10^-3 |
Units | string | MilliVolts |
TotalOutputPower | uint32 | |
Description | string | Represents the total output power of the PowerSupply in milliWatts. 0 denotes 'unknown'. |
MappingStrings | string | MIF.DMTF|Power Supply|004.21 |
PUnit | string | watt * 10^-3 |
Units | string | MilliWatts |
TypeOfRangeSwitching | uint16 | |
Description | string | TypeOfRangeSwitching describes the kind of input voltage range switching that is implemented in this PowerSupply. For example, autoswitching can be specified (value=4). |
MappingStrings | string | MIF.DMTF|Power Supply|004.16 |
ValueMap | string | 1, 2, 3, 4, 5, 6 |
Values | string | Other, Unknown, Manual, Autoswitch, Wide Range, Not Applicable |