Name | Data Type | Default Value | Qualifiers |
Name | Data Type | Value |
ActiveInputVoltage | uint16 | |
Description | string | ActiveInputVoltage indicates which input voltage range is currently in use. Range 1, 2, or both can be specified using the values 3, 4, or 5, respectively. If the Supply is not currently drawing power, the value 6 ("Neither") can be specified. This information is necessary in the case of a UPS, a subclass of PowerSupply. |
MappingStrings | string | MIF.DMTF|Power Supply|004.15 |
ValueMap | string | 1, 2, 3, 4, 5, 6 |
Values | string | Other, Unknown, Range 1, Range 2, Both, Neither |
InputPowerUnits | string | |
Description | string | Indicates the programmatic units for the Range1MaxInputPower and MaxInputPowerRange2 properties. |
Experimental | boolean | true |
ISPunit | boolean | true |
ModelCorrespondence | string | CIM_PowerSource.Range1MaxInputPower, CIM_PowerSource.Range2MaxInputPower |
IsACInput | boolean | |
Description | string | A value of true shall indicate the required input of the PowerSupply is alternating current (AC). A value of false shall indicate the required input for the PowerSource is direct current (DC). |
Experimental | boolean | true |
IsSwitchingSupply | boolean | |
Description | string | Boolean indicating that the PowerSupply is a switching (instead of linear) supply. |
NumberOfPhasesUtilized | uint32 | |
Description | string | NumberOfPhasesUtilized shall indicate the number of phases this power supply is configured to utilize. A value of zero shall indicate zero phases are utilized or this information is unknown. |
Experimental | boolean | true |
OutputPowerUnits | string | |
Description | string | Indicates the programmatic units for the MaxOutputPowerRange1, MaxOutputPowerRange2, and MaxOutputPower properties. |
Experimental | boolean | true |
ISPunit | boolean | true |
ModelCorrespondence | string | CIM_PowerSource.MaxOutputPowerRange1, CIM_PowerSource.MaxOutputPowerRange2 |
Override | string | OutputPowerUnits |
Range1InputFrequencyHigh | uint32 | |
Description | string | The frequency (in hertz) at the high end of the Input Frequency Range 1 of this Power Supply. A value of 0 implies DC. |
MappingStrings | string | MIF.DMTF|Power Supply|004.18 |
PUnit | string | hertz |
Units | string | Hertz |
Range1InputFrequencyLow | uint32 | |
Description | string | The frequency (in hertz) at the low end of the Input Frequency Range 1 of this Power Supply. A value of 0 implies DC. |
MappingStrings | string | MIF.DMTF|Power Supply|004.17 |
PUnit | string | hertz |
Units | string | Hertz |
Range1InputVoltageHigh | uint32 | |
Description | string | The high voltage of Input Voltage Range 1 for this Power Supply, in millivolts. A value of 0 denotes 'unknown'. |
MappingStrings | string | MIF.DMTF|Power Supply|004.8 |
PUnit | string | volt * 10^-3 |
Units | string | MilliVolts |
Range1InputVoltageLow | uint32 | |
Description | string | The low voltage of Input Voltage Range 1 for this Power Supply, in millivolts. A value of 0 denotes 'unknown'. |
MappingStrings | string | MIF.DMTF|Power Supply|004.7 |
PUnit | string | volt * 10^-3 |
Units | string | MilliVolts |
Range1MaxInputPower | uint32 | |
Description | string | Indicates the maximum amount of power that this PowerSupply may draw if the CIM_PowerSupply.ActiveInputVoltage has the value 2 or 3. The units of the value shall be described by the InputPowerUnits property. A value of zero shall indicate 'unknown'. |
Experimental | boolean | true |
ModelCorrespondence | string | CIM_PowerSupply.InputPowerUnits |
Range1MaxOutputPower | uint32 | |
Description | string | Indicates the maximum amount of power that may be drawn from this PowerSupply without causing a failure condition if the CIM_PowerSupply.ActiveInputVoltage has the value 2 or 3. The units of the value shall be described by the OutputPowerUnits property. A value of zero shall indicate 'unknown'. |
Experimental | boolean | true |
ModelCorrespondence | string | CIM_PowerSupply.OutputPowerUnits |
Range2InputFrequencyHigh | uint32 | |
Description | string | The frequency (in hertz) at the high end of the Input Frequency Range 2 of this Power Supply. A value of 0 implies DC. |
MappingStrings | string | MIF.DMTF|Power Supply|004.20 |
PUnit | string | hertz |
Units | string | Hertz |
Range2InputFrequencyLow | uint32 | |
Description | string | The frequency (in hertz) at the low end of the Input Frequency Range 2 of this Power Supply. A value of 0 implies DC. |
MappingStrings | string | MIF.DMTF|Power Supply|004.19 |
PUnit | string | hertz |
Units | string | Hertz |
Range2InputVoltageHigh | uint32 | |
Description | string | The high voltage of Input Voltage Range 2 for this Power Supply, in millivolts. A value of 0 denotes 'unknown'. |
MappingStrings | string | MIF.DMTF|Power Supply|004.12 |
PUnit | string | volt * 10^-3 |
Units | string | MilliVolts |
Range2InputVoltageLow | uint32 | |
Description | string | The low voltage of Input Voltage Range 2 for this Power Supply, in millivolts. A value of 0 denotes 'unknown'. |
MappingStrings | string | MIF.DMTF|Power Supply|004.11 |
PUnit | string | volt * 10^-3 |
Units | string | MilliVolts |
Range2MaxInputPower | uint32 | |
Description | string | Indicates the maximum amount of power that this PowerSupply may draw without causing a failure condition. The units of the value shall be described by the InputPowerUnits property. A value of zero shall indicate 'unknown'. |
Experimental | boolean | true |
ModelCorrespondence | string | CIM_PowerSupply.InputPowerUnits |
Range2MaxOutputPower | uint32 | |
Description | string | Indicates the maximum amount of power that may be drawn from this PowerSupply without causing a failure condition if the CIM_PowerSupply.ActiveInputVoltage has the value 4. The units of the value shall be described by the OutputPowerUnits property. A value of zero shall indicate 'unknown'. |
Experimental | boolean | true |
ModelCorrespondence | string | CIM_PowerSupply.OutputPowerUnits |
TotalOutputPower | uint32 | |
Description | string | Represents the total output power of the PowerSupply in milliWatts. 0 denotes 'unknown'. |
MappingStrings | string | MIF.DMTF|Power Supply|004.21 |
PUnit | string | watt * 10^-3 |
Units | string | MilliWatts |
TypeOfRangeSwitching | uint16 | |
Description | string | TypeOfRangeSwitching describes the kind of input voltage range switching that is implemented in this PowerSupply. For example, autoswitching can be specified (value=4). |
MappingStrings | string | MIF.DMTF|Power Supply|004.16 |
ValueMap | string | 1, 2, 3, 4, 5, 6 |
Values | string | Other, Unknown, Manual, Autoswitch, Wide Range, Not Applicable |
NominalPhaseWiring | uint32[] | |
Description | string | NominalPhaseWiring shall indicate the phases this power supply is configured to utilize. The actual phases from which the supply is drawing may vary. For example, a power supply that utilizes two phases and is wired to three phases may cycle through any combination. |
Experimental | boolean | true |
ValueMap | string | 0, 2, 3, 4 |
Values | string | Unknown, A, B, C |