Class CIM_Tachometer
extends CIM_NumericSensor

The use of this class is deprecated in lieu of the additions to Sensor and NumericSensor. A Tachometer can be defined by setting the SensorType property. inherited from Sensor, to 5 ("Tachometer").

Table of Contents
Hierarchy
Direct Known Subclasses
Class Qualifiers
Class Properties
Class Methods


Class Hierarchy

CIM_ManagedElement
   |
   +--CIM_ManagedSystemElement
   |
   +--CIM_LogicalElement
   |
   +--CIM_EnabledLogicalElement
   |
   +--CIM_LogicalDevice
   |
   +--CIM_Sensor
   |
   +--CIM_NumericSensor
   |
   +--CIM_Tachometer

Direct Known Subclasses

Class Qualifiers

NameData TypeValue
DeprecatedstringCIM_NumericSensor
DescriptionstringThe use of this class is deprecated in lieu of the additions to Sensor and NumericSensor. A Tachometer can be defined by setting the SensorType property. inherited from Sensor, to 5 ("Tachometer").
UMLPackagePathstringCIM::Device::Sensors
Versionstring2.8.0

Class Properties

Local Class Properties

NameData TypeDefault ValueQualifiers
NameData TypeValue
BaseUnitsuint1638
DeprecatedstringNo value
DescriptionstringThe base unit of the values returned by this Sensor. All the values returned by this Sensor are represented in the units obtained by (BaseUnits * 10 raised to the power of the UnitModifier). For example, if BaseUnits is Volts and the UnitModifier is -6, then the units of the values returned are MicroVolts. However, if the RateUnits property is set to a value other than "None", then the units are further qualified as rate units. In the above example, if RateUnits is set to "Per Second", then the values returned by the Sensor are in MicroVolts/Second. The units apply to all numeric properties of the Sensor, unless explicitly overridden by the Units qualifier.
ModelCorrespondencestringCIM_NumericSensor.UnitModifier, CIM_NumericSensor.RateUnits
OverridestringBaseUnits
ValueMapstring0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42, 43, 44, 45, 46, 47, 48, 49, 50, 51, 52, 53, 54, 55, 56, 57, 58, 59, 60, 61, 62, 63, 64, 65, 66
ValuesstringUnknown, Other, Degrees C, Degrees F, Degrees K, Volts, Amps, Watts, Joules, Coulombs, VA, Nits, Lumens, Lux, Candelas, kPa, PSI, Newtons, CFM, RPM, Hertz, Seconds, Minutes, Hours, Days, Weeks, Mils, Inches, Feet, Cubic Inches, Cubic Feet, Meters, Cubic Centimeters, Cubic Meters, Liters, Fluid Ounces, Radians, Steradians, Revolutions, Cycles, Gravities, Ounces, Pounds, Foot-Pounds, Ounce-Inches, Gauss, Gilberts, Henries, Farads, Ohms, Siemens, Moles, Becquerels, PPM (parts/million), Decibels, DbA, DbC, Grays, Sieverts, Color Temperature Degrees K, Bits, Bytes, Words (data), DoubleWords, QuadWords, Percentage, Pascals
RateUnitsuint164
DeprecatedstringNo value
DescriptionstringSpecifies if the units returned by this Sensor are rate units. All the values returned by this Sensor are represented in the units obtained by (BaseUnits * 10 raised to the power of the UnitModifier). This is true unless this property (RateUnits) has a value different than "None". For example, if BaseUnits is Volts and the UnitModifier is -6, then the units of the values returned are MicroVolts. But, if the RateUnits property is set to a value other than "None", then the units are further qualified as rate units. In the above example, if RateUnits is set to "Per Second", then the values returned by the Sensor are in MicroVolts/Second. The units apply to all numeric properties of the Sensor, unless explicitly overridden by the Units qualifier. Any implementation of CurrentReading should be qualified with either a Counter or a Gauge qualifier, depending on the characteristics of the sensor being modeled.
ModelCorrespondencestringCIM_NumericSensor.UnitModifier, CIM_NumericSensor.BaseUnits
OverridestringRateUnits
ValueMapstring0, 1, 2, 3, 4, 5, 6, 7, 8, 9
ValuesstringNone, Per MicroSecond, Per MilliSecond, Per Second, Per Minute, Per Hour, Per Day, Per Week, Per Month, Per Year
Resolutionuint32
DeprecatedstringNo value
DescriptionstringResolution indicates the ability of the Sensor to resolve differences in the measured property. The units for this measurement are determined by BaseUnit*UnitModifier/RateUnit.
MappingStringsstringMIF.DMTF|Temperature Probe|002.17, MIF.DMTF|Electrical Current Probe|001.17, MIF.DMTF|Voltage Probe|001.17
OverridestringResolution
PUnitstringrevolution / minute * 10^-1
UnitsstringTenths of Revolutions per Minute
SensorTypeuint165
DeprecatedstringNo value
DescriptionstringThe Type of the Sensor, e.g. Voltage or Temperature Sensor. If the type is set to "Other", then the OtherSensorType Description can be used to further identify the type, or if the Sensor has numeric readings, then the type of the Sensor can be implicitly determined by the Units. A description of the different Sensor types is as follows: A Temperature Sensor measures the environmental temperature. Voltage and Current Sensors measure electrical voltage and current readings. A Tachometer measures speed/revolutions of a Device. For example, a Fan Device can have an associated Tachometer which measures its speed. A Counter is a general purpose Sensor that measures some numerical property of a Device. A Counter value can be cleared, but it never decreases. A Switch Sensor has states like Open/Close, On/Off, or Up/Down. A Lock has states of Locked/Unlocked. Humidity, Smoke Detection and Air Flow Sensors measure the equivalent environmental characteristics. A Presence Sensor detects the presence of a PhysicalElement. A Power Consumption Sensor measures the instantaneous power consumed by a managed element. A Power Production Sensor measures the instantaneous power produced by a managed element such as a power supply or a voltage regulator. A pressure sensor is used to report pressure.
ModelCorrespondencestringCIM_Sensor.OtherSensorTypeDescription
OverridestringSensorType
ValueMapstring0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, .., 32768..65535
ValuesstringUnknown, Other, Temperature, Voltage, Current, Tachometer, Counter, Switch, Lock, Humidity, Smoke Detection, Presence, Air Flow, Power Consumption, Power Production, Pressure, DMTF Reserved, Vendor Reserved
UnitModifiersint321
DeprecatedstringNo value
DescriptionstringThe unit multiplier for the values returned by this Sensor. All the values returned by this Sensor are represented in the units obtained by (BaseUnits * 10 raised to the power of the UnitModifier). For example, if BaseUnits is Volts and the Unit Modifier is -6, then the units of the values returned are MicroVolts. However, if the RateUnits property is set to a value other than "None", then the units are further qualified as rate units. In the above example, if RateUnits is set to "Per Second", then the values returned by the Sensor are in MicroVolts/Second. The units apply to all numeric properties of the Sensor, unless explicitly overridden by the Units qualifier.
ModelCorrespondencestringCIM_NumericSensor.BaseUnits, CIM_NumericSensor.RateUnits
OverridestringUnitModifier

Inherited Properties

NameData TypeClass Origin
Accuracysint32CIM_NumericSensor
Availabilityuint16CIM_LogicalDevice
CaptionstringCIM_ManagedElement
CommunicationStatusuint16CIM_ManagedSystemElement
CreationClassNamestringCIM_LogicalDevice
CurrentReadingsint32CIM_NumericSensor
CurrentStatestringCIM_Sensor
DescriptionstringCIM_ManagedElement
DetailedStatusuint16CIM_ManagedSystemElement
DeviceIDstringCIM_LogicalDevice
ElementNamestringCIM_ManagedElement
EnabledDefaultuint16CIM_EnabledLogicalElement
EnabledStateuint16CIM_EnabledLogicalElement
ErrorClearedbooleanCIM_LogicalDevice
ErrorDescriptionstringCIM_LogicalDevice
HealthStateuint16CIM_ManagedSystemElement
Hysteresisuint32CIM_NumericSensor
InstallDatedatetimeCIM_ManagedSystemElement
InstanceIDstringCIM_ManagedElement
IsLinearbooleanCIM_NumericSensor
LastErrorCodeuint32CIM_LogicalDevice
LowerThresholdCriticalsint32CIM_NumericSensor
LowerThresholdFatalsint32CIM_NumericSensor
LowerThresholdNonCriticalsint32CIM_NumericSensor
MaxQuiesceTimeuint64CIM_LogicalDevice
MaxReadablesint32CIM_NumericSensor
MinReadablesint32CIM_NumericSensor
NamestringCIM_ManagedSystemElement
NominalReadingsint32CIM_NumericSensor
NormalMaxsint32CIM_NumericSensor
NormalMinsint32CIM_NumericSensor
OperatingStatusuint16CIM_ManagedSystemElement
OtherEnabledStatestringCIM_EnabledLogicalElement
OtherSensorTypeDescriptionstringCIM_Sensor
PollingIntervaluint64CIM_Sensor
PowerManagementSupportedbooleanCIM_LogicalDevice
PowerOnHoursuint64CIM_LogicalDevice
PrimaryStatusuint16CIM_ManagedSystemElement
RequestedStateuint16CIM_EnabledLogicalElement
StatusstringCIM_ManagedSystemElement
StatusInfouint16CIM_LogicalDevice
SystemCreationClassNamestringCIM_LogicalDevice
SystemNamestringCIM_LogicalDevice
TimeOfLastStateChangedatetimeCIM_EnabledLogicalElement
Tolerancesint32CIM_NumericSensor
TotalPowerOnHoursuint64CIM_LogicalDevice
TransitioningToStateuint16CIM_EnabledLogicalElement
UpperThresholdCriticalsint32CIM_NumericSensor
UpperThresholdFatalsint32CIM_NumericSensor
UpperThresholdNonCriticalsint32CIM_NumericSensor
AdditionalAvailabilityuint16[]CIM_LogicalDevice
AvailableRequestedStatesuint16[]CIM_EnabledLogicalElement
EnabledThresholdsuint16[]CIM_NumericSensor
IdentifyingDescriptionsstring[]CIM_LogicalDevice
OperationalStatusuint16[]CIM_ManagedSystemElement
OtherIdentifyingInfostring[]CIM_LogicalDevice
PossibleStatesstring[]CIM_Sensor
PowerManagementCapabilitiesuint16[]CIM_LogicalDevice
SettableThresholdsuint16[]CIM_NumericSensor
StatusDescriptionsstring[]CIM_ManagedSystemElement
SupportedThresholdsuint16[]CIM_NumericSensor

Class Methods

Inherited Class Methods

NameReturn TypeClass Origin
EnableDeviceuint32CIM_LogicalDevice
GetNonLinearFactorsuint32CIM_NumericSensor
OnlineDeviceuint32CIM_LogicalDevice
QuiesceDeviceuint32CIM_LogicalDevice
RequestStateChangeuint32CIM_EnabledLogicalElement
Resetuint32CIM_LogicalDevice
RestoreDefaultThresholdsuint32CIM_NumericSensor
RestorePropertiesuint32CIM_LogicalDevice
SavePropertiesuint32CIM_LogicalDevice
SetPowerStateuint32CIM_LogicalDevice