Name | Data Type | Value |
---|---|---|
Description | string | An AlarmDevice is a type of Device that emits audible or visible indications related to a problem situation. |
UMLPackagePath | string | CIM::Device::Sensors |
Version | string | 2.8.0 |
Name | Data Type | Default Value | Qualifiers | ||||
---|---|---|---|---|---|---|---|
Name | Data Type | Value | |||||
AlarmState | uint16 | ||||||
Description | string | The current state of the alarm. | |||||
ValueMap | string | 0, 1, 2, 3 | |||||
Values | string | Unknown, Off, Steady, Alternating | |||||
AudibleAlarm | boolean | ||||||
Description | string | Boolean indicating that the Alarm is audible. | |||||
AudioIndicatorIsDisabled | boolean | ||||||
Description | string | True indicates that the audio of an AlarmState indicator has been disabled (i.e. muted). A disabled state here does not imply that the AlarmState is off. | |||||
MotionAlarm | boolean | ||||||
Description | string | Boolean indicating that the Alarm causes motion of the Device. | |||||
MotionIndicatorIsDisabled | boolean | ||||||
Description | string | True indicates that the motion of an AlarmState indicator has been disabled (i.e. stopped). A disabled state here does not imply that the AlarmState is off. | |||||
Urgency | uint16 | ||||||
Description | string | Urgency is an enumerated value that indicates the relative frequency at which the Alarm flashes, vibrates and/or emits audible tones. | |||||
ValueMap | string | 0, 1, 2, 3, 4, 5, 6 | |||||
Values | string | Unknown, Other, Not Supported, Informational, Non-Critical, Critical, Unrecoverable | |||||
VisibleAlarm | boolean | ||||||
Description | string | Boolean indicating that the Alarm is visible. | |||||
VisualIndicatorIsDisabled | boolean | ||||||
Description | string | True indicates that the visual of an AlarmState indicator has been disabled (i.e. dimmed). A disabled state here does not imply that the AlarmState is off. |
Name | Data Type | Class Origin |
---|---|---|
AllocationState | string | CIM_LogicalDevice |
Availability | uint16 | CIM_LogicalDevice |
Caption | string | CIM_ManagedElement |
CommunicationStatus | uint16 | CIM_ManagedSystemElement |
CreationClassName | string | CIM_LogicalDevice |
Description | string | CIM_ManagedElement |
DetailedStatus | uint16 | CIM_ManagedSystemElement |
DeviceID | string | CIM_LogicalDevice |
ElementName | string | CIM_ManagedElement |
EnabledDefault | uint16 | CIM_EnabledLogicalElement |
EnabledState | uint16 | CIM_EnabledLogicalElement |
ErrorCleared | boolean | CIM_LogicalDevice |
ErrorDescription | string | CIM_LogicalDevice |
Generation | uint64 | CIM_ManagedElement |
HealthState | uint16 | CIM_ManagedSystemElement |
InstallDate | datetime | CIM_ManagedSystemElement |
InstanceID | string | CIM_ManagedElement |
LastErrorCode | uint32 | CIM_LogicalDevice |
LocationIndicator | uint16 | CIM_LogicalDevice |
MaxQuiesceTime | uint64 | CIM_LogicalDevice |
Name | string | CIM_ManagedSystemElement |
OperatingStatus | uint16 | CIM_ManagedSystemElement |
OtherEnabledState | string | CIM_EnabledLogicalElement |
PowerManagementSupported | boolean | CIM_LogicalDevice |
PowerOnHours | uint64 | CIM_LogicalDevice |
PrimaryStatus | uint16 | CIM_ManagedSystemElement |
RequestedState | uint16 | CIM_EnabledLogicalElement |
Status | string | CIM_ManagedSystemElement |
StatusInfo | uint16 | CIM_LogicalDevice |
SystemCreationClassName | string | CIM_LogicalDevice |
SystemName | string | CIM_LogicalDevice |
TimeOfLastStateChange | datetime | CIM_EnabledLogicalElement |
TotalPowerOnHours | uint64 | CIM_LogicalDevice |
TransitioningToState | uint16 | CIM_EnabledLogicalElement |
AdditionalAvailability | uint16[] | CIM_LogicalDevice |
AvailableRequestedStates | uint16[] | CIM_EnabledLogicalElement |
IdentifyingDescriptions | string[] | CIM_LogicalDevice |
OperationalStatus | uint16[] | CIM_ManagedSystemElement |
OtherIdentifyingInfo | string[] | CIM_LogicalDevice |
PowerManagementCapabilities | uint16[] | CIM_LogicalDevice |
StatusDescriptions | string[] | CIM_ManagedSystemElement |
Name | Data Type | Value |
---|---|---|
Description | string | SetAlarmState is a method for defining the current state of the Alarm. Its input parameter, RequestedAlarmState, is specified using the Values list of AlarmDevice's AlarmState property. SetAlarmState returns 0 if the request is successfully implemented, 1 if the specified RequestedAlarm State is not supported, and some other value if any other error occurred. In a subclass, the set of possible return codes should be specified using a ValueMap qualifier on the method. The strings to which the ValueMap contents are 'translated' should be specified as a Values array qualifier. |
Name | Type | Qualifiers | ||||
---|---|---|---|---|---|---|
Name | Data Type | Value | ||||
RequestedAlarmState | uint16 | |||||
Description | string | The desired state for the alarm. | ||||
IN | boolean | true | ||||
ValueMap | string | 0, 1, 2, 3 | ||||
Values | string | Unknown, Off, Steady, Alternating |
Name | Data Type | Value |
---|---|---|
Description | string | SetAlarmIndicator is a method for enabling or disabling the indicator of the AlarmState function, without changing the current AlarmState. It has 3 input parameters, Audio Indicator, VisualIndicator and MotionIndicator. For all of the input parameters, a value of 0 indicates no change to the AlarmState indicator, 1 indicates Disable, and 2 indicates Enable. The method returns 0 if the request is successfully implemented, 1 if the specified request is not supported, and some other value if any other error occurred. In a subclass, the set of possible return codes should be specified using a ValueMap qualifier on the method. The strings to which the ValueMap contents are 'translated' should be specified as a Values array qualifier. |
Name | Type | Qualifiers | ||||
---|---|---|---|---|---|---|
Name | Data Type | Value | ||||
AudioIndicator | uint16 | |||||
Description | string | The state for the audio indicator. | ||||
IN | boolean | true | ||||
ValueMap | string | 0, 1, 2 | ||||
Values | string | No Change, Disable, Enable | ||||
MotionIndicator | uint16 | |||||
Description | string | The state for the motion indicator. | ||||
IN | boolean | true | ||||
ValueMap | string | 0, 1, 2 | ||||
Values | string | No Change, Disable, Enable | ||||
VisualIndicator | uint16 | |||||
Description | string | The state for the visual indicator. | ||||
IN | boolean | true | ||||
ValueMap | string | 0, 1, 2 | ||||
Values | string | No Change, Disable, Enable |
Name | Data Type | Value |
---|---|---|
Description | string | SetUrgency is a method for defining the desired urgency level for the Alarm. Its input parameter, RequestedUrgency, is specified using the Values list of AlarmDevice's Urgency property. SetUrgency returns 0 if the request is successfully implemented, 1 if the specified Urgency level is not supported, and some other value if any other error occurred. In a subclass, the set of possible return codes should be specified using a ValueMap qualifier on the method. The strings to which the ValueMap contents are 'translated' should be specified as a Values array qualifier. |
Name | Type | Qualifiers | ||||
---|---|---|---|---|---|---|
Name | Data Type | Value | ||||
RequestedUrgency | uint16 | |||||
Description | string | Desired urgency for the alarm. | ||||
IN | boolean | true | ||||
ValueMap | string | 1, 3, 4, 5, 6 | ||||
Values | string | Other, Informational, Non-Critical, Critical, Unrecoverable |
Name | Return Type | Class Origin |
---|---|---|
EnableDevice | uint32 | CIM_LogicalDevice |
OnlineDevice | uint32 | CIM_LogicalDevice |
QuiesceDevice | uint32 | CIM_LogicalDevice |
RequestStateChange | uint32 | CIM_EnabledLogicalElement |
Reset | uint32 | CIM_LogicalDevice |
RestoreProperties | uint32 | CIM_LogicalDevice |
SaveProperties | uint32 | CIM_LogicalDevice |
SetPowerState | uint32 | CIM_LogicalDevice |